1www.rletech.comNovember 9, 2011Facility MonitoringPresented by:Chris Ihfe
10www.rletech.comLeak Detection Cables• Designed for open areas and to encapsulate areas of concern• Unique Sensing Cables to detect:– Conductive f
11www.rletech.comLeak Detection Cable (SC)• Detects any conductive fluid• Patented design• Quick dry / quick reset• Plenum rated – CL2P• For use
12www.rletech.comLeak Detection Cable (SC-H)• Hydrocarbon (liquid fuel) detection cable• Other fluids will not create an alarm condition• Current d
13www.rletech.comLeak Detection Cable (SC-C)• Chemical Sensing Cable• Used to detect:– Acids– Bases– Other conductive harmful fluids• Can be cle
14www.rletech.comZone Controllers• Ideal for Sensing Cable installed in open areas where the Sensing Cable is visible• Identifies that fluid is in c
15www.rletech.comSingle Zone ControllersNovember 9, 2011LD300 LD1000EnclosurePlastic MetalPowerrequirements5VDC 24VACorDCMax.SensingCable300ft/9
16www.rletech.comMultiple Zone ControllersNovember 9, 2011LDRA6EnclosureMetalPowerrequirements24VACorDCInputs6SensingCablemax.length1000ft/305m
17www.rletech.comDistance Read Controllers• Ideal for longer runs of Sensing Cable and Sensing Cable installed in concealed areas• Identifies the lo
18www.rletech.comDistance Read ControllersNovember 9, 2011SeaHawk 10K LD1500 LD2100 LD5100Maximumsensingcable 10,000ft/3048m* 1,500ft/457m 5,000ft
19www.rletech.comSeaHawk Virtual / Physical ZonesNovember 9, 2011(Available only on the LD2100 & LD5100)Virtual Zones•Distance to the leak determi
2www.rletech.com• Established in 1984• Focused on developing equipment to help minimize downtime• Standard, Scalable & Custom Solutions• Produ
20www.rletech.comSeaHawk AccessoriesNovember 9, 2011FM1114WCCS-50J-clips (JC-xxx)X-CONLD-ENC/-NPNon Sensing Cable (NSC)
21www.rletech.comSeaHawk AccessoriesNovember 9, 2011• Non-sensing cable (NSC-xx)– Used between lengths of sensing cable– Does not add resistance• J
22www.rletech.comSeaHawk AccessoriesNovember 9, 2011• Weighed cable connector (WCCS-50)– Creates distinct separation between lengths of Sensing Cabl
23www.rletech.comNovember 9, 2011Alarm Monitoring & Notification Products
24www.rletech.comAlarm monitoring and notification products• Stand-alone appliance and easily integrated• No recurring costs• Scalable• In-band an
25www.rletech.comNovember 9, 2011• Stand-alone monitoring appliance with redundant direct alarm notification- In-band (network)- Out-of-band (optio
26www.rletech.comWhat can Falcon products monitor?November 9, 2011Any device that provides any of the following output signals: Dry Contact, 4-20mA, 0
27www.rletech.comWhat can Falcon products monitor?November 9, 2011Any device that provides any of the following output signals: Dry Contact, 4-20mA, 0
28www.rletech.comHow are alerts sent?November 9, 2011F110 Wirelessgateway F3400 FMSDirectNotification– Network*Singleemailaddress(ordistro list
29www.rletech.comInput detailsNovember 9, 2011F110 Wireless GatewayF3400 FMSProprietarysensors3inputsfor temperatureor temperature/ humidity
3www.rletech.comLeading Causes of Business Downtime*November 9, 2011*Source: Contingency Planning Research, a division of Eagle Rock Alliance0%5%10%15
30www.rletech.comFalcon FMS – Web InterfaceAlarm Status:• Unique input labels can be displayed for alarm and normal conditions• Labels are color cod
31www.rletech.comFalcon FMS – Web InterfaceIP Linking:• Up to 10 IP links can be integrated on the main page.• The image is a link to open up the IP
32www.rletech.comFalcon FMS – Web InterfaceSimplified Power Monitoring:• Monitor the main power feeds and/or each individual circuit• Alarm threshol
33www.rletech.comFalcon FMS – Web InterfaceLinks to Graphical User Interface:• Floor plan can be uploaded to the FMS as a .jpg file• Integrated inpu
34www.rletech.comNovember 9, 2011Falcon FMS – Custom Map
35www.rletech.comFalcon FMS – Custom MapFMS GUI: • Can display up to 284 inputs (104 directs inputs + 180 Modbus or SNMP values)• The size of the im
36www.rletech.comFalcon FMS – “Nest”View multiple RLE products on a single page:• Displays the status from as many as 32 Falcon products and/or SeaHa
37www.rletech.comFalcon FMS – “Nest” MapA .jpg image (map) can be uploaded as a background image•Integrated products displayed as color coded points o
38www.rletech.comFalcon FMS – PDA ViewAlarm statuses can also be viewed with a PDA or mobile deviceNovember 9, 2011
39www.rletech.comFalcon FMS – Data LoggingInternal logs stored in non-volatile memory• Last 256 alarms – Color coded to identify:– Acknowledged– Un
4www.rletech.comLeading Causes of Business Downtime*November 9, 20110%5%10%15%20%25%30%Power OutageWater DamageHardware FailureEarthquake Fire Hurrica
40www.rletech.comFalcon FMS – Data Logging GraphInternal logging:• Stored on the FMS – no external software required• Available as a graph or downlo
41www.rletech.comFalcon FMS – Input Configuration PageSimple Configuration:• Drop down menus to select input types• Multiple alarm thresholds• Desc
42www.rletech.comFalcon FMS – SchedulesTwo configurable schedules:• Controls the relay outputs and commonly used to turn equipment on/off• Identify
43www.rletech.comFalcon FMS – InputsHardwired Inputs:• Dry Contacts, 4-20mA, 0-5VDC and 0-10VDC signals• Scalable from 8 to104• No proprietary conn
44www.rletech.comFalcon FMS – ExpansionFMS Enclosures:FMS-x (1RU) 8 Inputs, each selectable as NO/NC Dry Contact or 4-20mA2 NO/NC Dry Contact outputs
45www.rletech.comFalcon FMS – Expansion OptionsFMS Expansion Cards:EXP-A-24/48 12 Inputs, each configurable to accept- Digital Dry Contact input- 4
46www.rletech.comFalcon FMS – OutputsDry Contact, Form “C” Relay Outputs:• Scalable from 2 to 34• Event driven– By alarm conditions exceeding accep
47www.rletech.comFalcon FMS – Access• All information can be viewed and the FMS can be configured with a Web Browser– Access through network– Acces
48www.rletech.com• A receiver for up to 400 418MHz / 900MHz wireless devices• Provides direct alarm notification (4 email addresses)• Protocols for
49www.rletech.comCan be used as a Network router sending signals to a centralized unit for a single view of multiple units.Wireless Gateway – FDS-WiNo
5www.rletech.comSite Monitoring Best Practices• Identify issues before they become critical!– Snowballing effect – Issues usually start small– Loca
50www.rletech.com• Maximum integrated transmitters:– Without a Point Repeater – 100– With use of a Point Repeater – an additional 300• Wireless dis
51www.rletech.comSite Monitoring - Reactive• Facility lost one of the three phases of utility power• Computer Room Air A/C units continued to run un
52www.rletech.comSite Monitoring Best Practices - Proactive• Power meters installed on the utility feed• Intelligent information pulled from the CRA
53www.rletech.comSite Monitoring - Reactive• Generator block heater stuck on• Normal average is 120 degrees when not running• Block reached 150 deg
54www.rletech.comSite Monitoring Best Practices - Proactive• Generator alarms integrated into a monitoring system• Alarms trigger when temperatures
55www.rletech.comThe Falcon SolutionNovember 9, 2011• Direct alarm notification ensures that the right people are aware of issues before they become
56www.rletech.comFalcon alarm monitoring & notificationNovember 9, 2011• Even equipment with no alarming capabilities can easily be retrofitted t
57www.rletech.comSite Monitoring• Every site is unique• Understand budget restrictions• Establish immediate needs• Identify long term goals• Know
58www.rletech.comFalcon alarm monitoring & notificationNovember 9, 2011• Are all available sensors and alarm signals integrated into an alarm not
59www.rletech.comSite Monitoring Best Practices• Integrate all existing equipment and sensors– Summary alarm outputs are available from most critica
6www.rletech.comThe Impacts of Downtime• Redirection of efforts towards recovery• Employee productivity and moral• Customer ConfidenceNovember 9, 2
60www.rletech.comNovember 9, 2011• Vendor neutral systems that simplify designing the best solution• Eliminate recurring costs • A cost effective w
61www.rletech.comNovember 9, 2011Alarm Monitoring & Notification ProductsQuestions?
7www.rletech.comNovember 9, 2011Leak Detection
8www.rletech.comSpot Detectors• Designed for confined areas• Potted electronics = submersible design• Corrosion resistant, no exposed metal• No vi
9www.rletech.comSpot DetectorsNovember 9, 2011SD‐RO1 SD SD‐Z SD‐Z1Power24VAC/DC* Falcon SeaHawk controller SeaHawk controllerAudible‐ ‐ ‐ ‐OutputForm